Overview:

Maintenance Bypass and Output Distribution Accessory

This unit allows manual transfer of connected equipment to utility power via a maintenance bypass switch, permitting scheduled maintenance or UPS replacement without disrupting data center power.​​​​​

When a computer system cannot be without power — even for maintenance — a Liebert MicroPOD ensures continuous uptime. The Liebert MicroPOD provides maintenance bypass capability and power output distribution for Liebert GXT and Liebert PSI UPS models 3 kVA and below, as well as other brands of UPS systems. It allows removal of the UPS without powering down the connected equipment.

The Liebert MicroPOD maintenance bypass and power output distribution switch allows you to manually transfer the connected equipment to utility power via a maintenance bypass switch, permitting scheduled maintenance or UPS replacement without discontinuing power to the critical load. Transferring back to UPS power is just as easy — simply turn the switch to the indicated position and the load is protected by the UPS. Available in plug-andplay or hardwired options at 120V or 208V rating, units include brackets for rack mounting in any direction.

ConfigurationHigher Availability

  • Provides utility power to attached equipment when switched to maintenance bypass mode.
  • Allows UPS maintenance or replacement of the UPS without discontinuing power to critical equipment.

Flexibility

  • Easily installed — the UPS and utility power are both connected to the MicroPOD with the supplied cords.
  • Allows scheduled UPS maintenance to ensure continuous uptime without having to shut down protected equipment.
  • Rotary switch with indicators make the unit simple to operate.
  • Plug-and-play connectability for both input and output.
  • Compatible with any brand of UPS system.

Lowest Total Cost Of Ownership

  • Assures system uptime during maintenance activities.
  • Extreme affordability.
  • Two-year, no-hassle replacement warranty eliminates the cost of replacement during the warranty period.

Features and Benefits:

Protecting the Edge of Your Vulnerable NetworkBenefits

  • Flexible plug-and-play connectability for both input and output.
  • Easy to use rotary switch and indicators make the unit simple to operate.
  • Compatible with any brand of UPS system.
  • Improved availability by routing utility power to attached equipment
  • Allows UPS maintenance or replacement of the UPS without discontinuing power to critical equipment.
  • Easy to install and operate
  • Includes electrical cords
  • Cost effective bypass.
  • Two-year, no-hassle replacement warranty eliminates the cost of replacement during the warranty period.
  • Use with any brand of UPS, 3kVA or smaller

Features

  • Manual switchover from UPS to utility power
  • Allows continuous operation for connected equipment during UPS maintenance or replacement
  • Installs with plug-and-play ease
  • Operates with any brand of UPS, 3kVA or smaller

Specifications:


Part Number Plug to Utility Receptacle to Input Plug to UPS Output MicroPOD Output Receptacles
120V UL Listed MicroPODs
MP2-115A 5-15P 5-15R 5-15P (8) 5-15R
MP2-120C 5-20P 5-20R 5-20P (8) 5-20R (T-Slot)
MP2-130C L5-30P L5-30R L5-30P (8) 5-20R (T-Slot)
MP2-130E L5-30P L5-30R L5-30P (2) 5-15R, (4) 5-20R (T-Slot) (1) L5-30R
MP2-130P L5-30P L5-30R L5-30P (4) 5-15R, (2) L5-20R
MP2-115HW Hardwired 5-15R 5-15P Hardwired
MP2-120HW Hardwired 5-20R 5-20P Hardwired
MP2-130HW Hardwired 5-30R 5-30P Hardwired
208V UL Listed MicroPOD
MP2-220N L6-20P OR Hardwire Connection (plug is removable for hardwire applications) L6-20R L6-20P (2) L6-20R, (2) L6-15R, OR Hardwire Connections (receptacles are removable for hardwire applications)
230V CE Marked MicroPODs
MP2-210K EN60320/C14 EN60320/C13 EN60320/C14 (4) EN60320/C13
MP2-220L EN60320/C20 EN60320/C19 EN60320/C20 (4) EN60320/C13, (1)EN60320/C19

Views:


Front View

Rear View

Installed


Documentation:

Download the Vertiv Liebert MicroPOD Datasheet (.PDF)

Pricing Notes:

Vertiv Products
120V UL Listed MicroPODs
Vertiv Liebert MicroPOD MP2-115A
#MP2-115A
Get a Quote!
Vertiv Liebert MicroPOD MP2-120C
#MP2-120C
Get a Quote!
Vertiv Liebert MicroPOD MP2-130C
#MP2-130C
Get a Quote!
Vertiv Liebert MicroPOD MP2-130E
#MP2-130E
Get a Quote!
Vertiv Liebert MicroPOD MP2-130P
#MP2-130P
Get a Quote!
120V UL Listed MicroPODs Hardwired
Vertiv Liebert MicroPOD MP2-115HW Hardwired
#MP2-115HW
Get a Quote!
Vertiv Liebert MicroPOD MP2-120HW Hardwired
#MP2-120HW
Get a Quote!
Vertiv Liebert MicroPOD MP2-130HW Hardwired
#MP2-130HW
Get a Quote!
208V UL Listed MicroPOD
Vertiv Liebert MicroPOD 208V/20A W/ MBS HDWR
#MP2-220N
Get a Quote!
230V CE Marked MicroPODs
Vertiv Liebert MicroPOD 230V 10A
#MP2-210K
Get a Quote!
Vertiv Liebert MicroPOD 230V 2K
#MP2-220K
Get a Quote!
Vertiv Liebert MicroPOD 230V 16A
#MP2-220L
Get a Quote!

The Liebert EXS UPS delivers simplicity, reliability and efficiency in a compact three phase power solution. The integrated design and reduced footprint provides maximum power capacity. Robust availability is ensured from the integrated maintenance bypass and advanced monitoring capabilities. Flexibility is enhanced using output distribution and variable battery runtime options. Low TCO is maintained from the high operating efficiency levels and reduced installation costs